Optimus+ GPS Add-on for Sound Level Meters
Microphones & AccessoriesGeotag all your sound measurements with the Optimus+ GPS add-on for sound level meter, designed to make accurately logging the locations of your environmental noise measurements easier.
- Available as a bolt of for existing Optimus meters or available as a standalone kit
- Automatically geotags every measurement that’s taken
- Time to First Fix (TTFF) under 60 seconds
- Easily view the location of every measurement a Google map format within Noise Tools software
- Easily removed when not in use to extend the battery life of your meter
Optimus+ GPS Add-on for Sound Level Meters
Easily geotag all your sound measurements
We’ve designed the Optimus+ GPS add-on for our sound level meters to make logging the locations of your environmental noise measurements easier. Simply connect the module to the base of your Optimus+ Industrial or Environmental to see accurate geo-location data for every measurement you take.
How will the Optimus+ GPS add-on benefit your organisation?
Perfect for environmental noise assessments or outdoor occupational noise surveys, the benefit of precise GPS location data will help you understand noise levels in more detail than ever before. Not only does Optimus+ GPS add-on for Sound Level Meters provide accurate positioning data, but as all our users have come to expect, this instrument comes fully loaded with a host of features and functionality to provide the comprehensive solution to environmental and occupational noise measurement available on the market.
Time to First Fix
Our GPS Module has an industry-leading Time to First Fix (TTFF). NoiseTools automatically downloads GPS AssistNow data to instruments configured to use the GPS Module this helps reduce the TTFF from up to 5 minutes to under 60 seconds.
View all of your data in NoiseTools
As well as being able to see the geotagged data for every measurement on the screen of your Optimus+ GPS enabled sound level meter, you can also view the location data in NoiseTools:
In addition, you can use the View Map button in NoiseTools to view your data on a map or Google Earth image and add these to your assessment reports.
Add on GPS Module that integrates directly with Optimus+ Red and Optimus+ Green sound level meters.
Applicable standards2
IEC 61672-1:2013 Class 1 or Class 2
IEC 61672-1:2002 Class 1 or Class 2 Group X IEC 60651:2001 Type 1 I or Type 2 I
IEC 60804:2000 Type 1 or Type 2
IEC 61252:1993 Personal sound exposure meters ANSI S1.4 -1983 (R2006), ANSI S1.43 – 1997 (R2007)
ANSI S1.25:1991
IEC 61260:1996 & ANSI S1.11-2004
DIN 45657:2005-03
Microphone
Class 1 Instruments MK:224/MK:229 pre-polarized Class 2 Instruments MK:216 pre-polarized
Microphone preamplifier
MV:200 removable preamplifier (All Versions)
Total measurement range:
20dB to 140dB RMS single range
Noise floor: <18dB(A) Class 1, <21dB(A) Class 2
Frequency weightings
RMS & peak : A, C, & Z measured simultaneously 1:1 octave bands: 31.5Hz to 16kHz
1:3 octave bands: 6.3Hz to 20kHz (bands from 12.5Hz displayed, 6.3Hz, 8Hz & 10Hz stored & downloaded)
Additional metrics: LAeq LF (20Hz to 200Hz) & Leq LF (20Hz to 200Hz)
Time weightings
Fast, Slow & Impulse measured simultaneously
Display
High-resolution display
Ambient light sensor and illuminated keypad
Memory
8GB (32GB factory fit option)
AuditStore
Measurement verification data stored in secure memory
Time history data rates (global settings)
10ms, 62.5ms, 100ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (user-selectable)
VoiceTag audio recording
Up to 30 seconds of audio notes with each measurement
Acoustic fingerprint audio recording
Off, manual, threshold triggered, advanced trigger User options:
Studio quality – 96kHz/32bit WAV format
High quality – 48kHz/24bit WAV format
Standard quality – 16kHz/16bit WAV format Pre-Trigger & Post-Trigger
Integrators
Three simultaneous “virtual” noise meters. Integrator 1 is preset to Q3 for Leq functions. Integrators 2 & 3 can be configured with the following:
Exchange rate: 3, 4 or 5 dB
Threshold: 70dB to 120dB (1 dB steps) Time weighting: None or slow
Criterion level: 70dB to 120dB (1 dB steps) Criterion time: 1 to 12 hours in 1 hour steps
Integrator quick settings
EU, OSHA HC & OSHA NC, OSHA HC & ACGIH, MSHA HC & MSHA EC, Custom 1 & Custom 2
Ln statistical values
14 independent statistical Ln values calculated from 1/16th LAF
7 preset to L1.0, L5.0, L10.0, L50.0, L90.0, L95.0 & L99.0
7 user defined Ln values
CR:172C & CR:171C allow for an additional 14 Ln values with independent time and frequency weighting.
Measurement control
Single or repeat measurement control with user selectable duration of manual, 1 min, 5 min, 10 min, 15 min, 30 mins, 1 hour, Lden
Automatic synchronisation and repeat
Pause
Back-erase with user selectable duration
Dimensions
Size: 283mm x 65mm x 30mm Weight: 300gms/10oz
Batteries
4 x AA alkaline
Battery life
Typically 12 hours with alkaline AA
Typically 20 hours with lithium AA non-rechargeable
Battery life is dependent upon the battery type and quality, and screen brightness
Connections
USB Type B to PC
AC & DC output via ZL:174 (2 x Phono, 1m) Multi-pin IO for external power via ZL:171 cable (2.1mm socket)
External power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket)
Tripod Mount
1/4” Whitworth socket
Case
Material: high-impact ABS-PC with soft touch back and keypad
Environmental conditions
Temperature: Humidity:
Electromagnetic performance
IEC 61672-1:2002 & IEC 61672-2:2003
Except where modified by EN 61000-6-1:2007 & EN 61000-6-1:2007
Language options
English, French, German, Spanish as standard Other language options may be available
Software support
NoiseTools download, configuration and analysis software supplied as standard. Compatible with Microsoft Windows 7, 8 & 10 (32bit & 64bit)
Bluetooth
BLE compatible with Anrdoid and iOS devices Cirrus mobile applications available from Google Play and the App Store
GPS Location Accuracy
GNSS: Horizontal positional accuracy
GPS & GLONASS: 2.5m
GPS: 2.5m
GLONASS: 8.0m
Galileo: TBC
Based on CEP, 50%, 24 hours static, good sky view
CR:152B & CR:151B
Displayed functions
LXY, LXYMax, LXYMin
Measurement run time
Stored functions
LXYMax & time history of LXYMax
CR:162B & CR:161B
Displayed functions
LXY, LXYMax, LXYMin,,LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq
Graph of short LAeq, LCPeak
Measurement run time
Integrators 2 & 3: TWA, dose%, est dose%
Stored functions
LXYMax & time history of LXYMax
LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak
Time history of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators 2 & 3: LAVG , TWA. %dose
Time history of LAVG
CR:162C & CR:161C
Displayed functions
LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq
Graph of short LAeq, LCPeak
Measurement run time
Integrators 2 & 3: TWA, dose%, est dose%
Real-time octave band filters
NR & NC values & curves
Stored functions
LXYMax & time history of LXYMax
LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak
Time history of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators 2 & 3: LAVG , TWA. %dose
Time history of LAVG
Octave Bands: Overall Leq & Leq Time History for each band
NR & NC values & curves
Measurement run time
Time & date of measurement start
CR:1720 & CR:1710
Displayed functions
LXY, LXYMax, LXYMin
LXeq, LCPeak, LZPeak, LAPeak LCeq-LAeq, LXE, LAIeq
Graph of short LAeq, LCPeak
Measurement run time
Integrators 2 & 3: TWA, dose %, est dose % 14 statistical Ln% values
Stored functions
LXYMax and time history of LXYMax
LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Time history of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators 2 & 3: LAVG , TWA. % dose Time history of LAVG
Ln Values: 14 independent statistical values Audio recording during measurement
Time, date and duration of measurement
CR:172A & CR:171A
Displayed functions
LXY, LXYMax, LXYMin
LXeq, LCPeak, LZPeak, LAPeak LCeq-LAeq, LXE, LAIeq
Graph of short LAeq, LCPeak
Measurement run time
Integrators 2 & 3: TWA, dose %, est dose % Real-time 1:1 octave bands (graphical and numerical)
NR & NC values and curves
14 statistical Ln% values
Stored functions
LXYMax and time history of LXYMax
LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Time history of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators 2 & 3: LAVG , TWA. % dose
Time history of LAVG
1:1 octave bands: overall Leq & Leq time history for each band, NR & NC values and curves
Ln values: 14 independent statistical values Audio recording during measurement
Time, date and duration of measurement
CR:172C & CR:171C
Displayed functions
LXY, LXYMax, LXYMin
LXeq, LCPeak, LZPeak, LAPeak LCeq-LAeq, LXE, LAIeq
Graph of short LAeq, LCPeak
Measurement run time
Integrators 2 & 3: TWA, dose %, est dose % Real-time 1:1 octave bands (graphical and numerical)
Real-time 1:3 octave bands (graphical and numerical)
Tonal noise detection in 1:3 octave bands NR & NC values and curves
Leq LF (20Hz to 200Hz)
Up to 28 statistical Ln% values
Stored functions
LXYMax & time history of LXYMax
LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Time history of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators 2 & 3: LAVG , TWA. % dose
Time history of LAVG
1:1 & 1:3 octave bands: overall Leq & Leq time history for each band
Tonal noise detection in 1:3 octave bands
NR & NC values and curves
Ln values: 28 independent statistical values Audio recording during measurement
Time, date and duration of measurement
where x=A ,C or Z y= F, S or I
Other functions may be calculated by the NoiseTools software and displayed on download.
Notes
1. Please contact Cirrus Research plc for details of the standards and approvals that are available on specific instrument types.
2. For details of the displayed and stored parameters, please refer to the Optimus user manual for full specifications.
All specifications, features and values are typical and are subject to change without notice.