Revo Hand-Arm and Whole-Body Vibration Measurement Kit

Human Vibration Meters

The Revo Hand-Arm and Whole-Body Vibration Measurement Kit that gives you all the data to complete your vibration assessments while complying with the Control of Vibration at Work Regulations 2005 and ISO 2631.

  • Hand-Arm Vibration measurements for the Control of Vibration at Work Regulations 2005
  • Whole-Body Vibration measurements in accordance with ISO 2631
  • Easily switch between hand-arm and whole-body measurements
  • FFT display for identification of dominant frequencies
- +
SKU: CK31HAWB
Tags:

The Revo Hand-Arm and Whole-Body Vibration Measurement Kit

Hand-arm and Whole-body vibration measurements made easy

The Revo Hand-Arm and Whole-Body Vibration Measurement Kit provides a simple and convenient way to measure, analyse and assess exposure to vibration in accordance with standards such as ISO 5349 and European Directive 2002/44/EC.

Capable of measuring four channels simultaneously, the Revo Vibration Meter meets the requirements of ISO 8041:2005 and is ideal for assessing Hand-Arm and Whole Body Vibration Exposure and can help reduce the incidence of painful conditions such as Hand-Arm Vibration Syndrome (HAVS), back pain, and spinal injury associated with over-exposure of vibration.

Hand-Arm vibration measurements in accordance with the Control of Vibration at Work Regulations 2005
Whole Body vibration measurements in accordance with ISO 2631
Easily switch between hand-arm and whole-body measurements
Four independent measuring channels with IEPE inputs and TEDS support
3-channel integrated frequency analysis (FFT) for the detection of main frequencies
Stores up to 10,000 measurements and up to 1,000 FFT Measurements
Colour screen display of running and interval measurement values
USB interface for quick download of your data
Includes a free reporting package to analyse your data

Vibration exposure

The Revo vibration meter gives you the Vector Sum m/s2 (of the triaxial vibration measurement consisting of X, Y and Z) of individual tools, and also m/s2 A(8) vibration exposure over your average over a working day.

The Revo Hand-Arm and Whole-Body Vibration Measurement Kit gives you the Vector Sum m/s2 A(8) vibration exposure over your average over a working day for both hand-arm and whole-body vibration. You can easily switch between the two measurements.

For hand-arm vibration the recommended exposure action value (EAV) is a daily exposure of 2.5 m/s2 A(8), exposure equal to or above this requires you to put control measures in place. The exposure limit value (ELV) is a daily exposure of 5 m/s2 A(8). It represents a high risk above which no employee not be exposed.

For whole-body vibration the exposure action value (EAV) is 0.5 m/s2 A(8) this is the level that employers should introduce technical and organisational measures to reduce their employees exposure, and the exposure limit value (ELV) is 1.15 m/s2 A(8) this is the maximum level of vibration that should not be exceeded.

You can out more about Human Vibration measurement here.

Analyse Your Data

Revo Software

Import the data from your Revo Vibration Meter for the easy calculation of Daily Vibration Exposure A(8) for hand-arm and whole-body vibration.

Download SoftwareDownload USB Drivers
Image link
Compliant reporting
Contains information required for ISO 2631 or ISO 5349
A(8) calculation
Automatically calculate A(8) values from imported data
Simple import
Easily import from your Revo Vibration Meter
Monitor exposure
Assign people and activities to your results
Revo Human Vibration Meter Software

Standards

ISO 8041:2005 ISO 5349-1:2001 ISO 5349-2:2001

Measurements

Human Vibration (Acceleration)

Interval RMS, vector sum, max. running RMS (MTVV), vibration dose value (VDV)

Acceleration, Velocity & Displacement

Running RMS, maximum RMS, vector sum, peak value, maximum peak value

Daily exposure A(8)

A(8) calculation for different activities and test persons via software

Frequency analysis (FFT)

125 lines for X/Y/Z, peak spectrum of acceleration 3 – 240 / 6 – 480 / 12 – 960 / 24 – 1920 Hz

Weighting Filters

Wb, Wc, Wd, Wh, Wj, Wk, Wm Unweighted: 6.3Hz – 1259 Hz (H/A) / 0.4Hz – 100 Hz (G/K)

Frequency Range

Acceleration: 0.1 – 2000 Hz / 1 – 1000 Hz

Velocity: 1 – 100 Hz / 2 – 1000 Hz / 10 – 1000 Hz

Displacement: 5 – 250 Hz

Channels

4 low-power IEPE inputs TEDS support (IEEE1451.4, Template 25)

Measurement Range

Acceleration: 800 m/s²

Velocity: 100 – 10000 mm/s

Displacement: 250 – 15000 μm

Linearity Range

> 75 dB for ± 6 % error

Noise Floor

< 0,003 m/s² Sensor Input

Low-power IEPE, sensitivity 0.8 – 120 mV/ms-²

Memory

Up to 10,000 measurements Up to 1,000 FFTs Each measurement stored with date, time and comments

Display

Colour OLED

USB Interface

USB 2.0 via ZL:311 cable

Power

3 x AAA Alkaline LR03 Typically 10-14 hours operation

Environmental

Temperature: -20°C to 60 °C Humidity: Up to 95% RH Noncondensing

Dimensions (without connectors)

125 mm x 65 mm x 27 mm

Weight

140gms

User Manual (pdf, 1939KB)
English
User Manual (pdf, 2108KB)
German
User Manual (pdf, 2106KB)
French
User Manual (pdf, 1543KB)
Spanish
Datasheet (pdf, 207KB)
English
Datasheet (pdf, 221KB)
German
Datasheet (pdf, 188KB)
French