Original doseBadge
Noise DosimetersThe Original doseBadge noise dosimeter is a wireless personal sound exposure meter for performing occupational and industrial hygiene noise measurements of personal noise exposure.
- The original wireless personal dose meter
- IEC 61252 and ANSI S1.25 Personal Sound Exposure Meter Standards
- Dual channel instrument
- LAeq, LCpeak and exposure value parameters
- Tough, robust metal case perfect for working environments
- Free NoiseTools software for analysis and reporting
Description
The Original doseBadge
Everything you need for occupational noise and industrial hygiene measurements
The doseBadge noise dosimeter system is the perfect solution for measuring a worker’s noise dose exposure. The badge is small and light, with no cable or controls and mounts comfortably on the worker’s shoulder. The dosimeter is then left on the worker, storing details about the noise levels throughout the day.
The doseBadge has no controls or display and all control is over the infra-red link to the Reader. The doseBadge case is a lightweight alloy, giving added strength to the already strong cone shape.
The Original doseBadge noise dosimeter is a dual-channel instrument that will measure, store, and calculate the parameters essential for compliance with occupational noise regulations.
These include LAeq, LCPeak & LEP,d and % Dose, LAVG & TWA. Along with these overall values, the Original doseBadge will store a Time History, or Noise Profile, throughout the measurement, for both channels.
The Original doseBadge survives in the harshest environments
The Original doseBadge has been designed to survive in the toughest and harshest environments. There are no cables, controls or displays to damage, and the microphone, battery and electronics are all housed in a robust and lightweight metal case which is strong enough to withstand being dropped, knocked or even stood on.
Applications for the Original doseBadge Noise Dosimeter
Due to its unique and robust design, the doseBadge is used across a wide range of applications where there is a need to assess workers’ noise exposure, such as:
Personal Noise Monitoring
Watch the product video to find out how the Original doseBadge makes monitoring personal noise exposure easier than ever.
Using the Original doseBadge Noise Dosimeter
Each Complete Kit is supplied with a Reader unit. One Reader can be used to control as many doseBadges as you need.
The Reader is used to carry out the following functions:
The Reader has a built in Calibrator, operating at 1 kHz, 114 dB.
To calibrate the dosimeter, simply push it into the calibration cavity and press the Cal button on the Reader. The calibration process is automatic and the results are recorded, along with any automatic adjustments that are made.
The Reader unit can also be used to configure the doseBadge settings. The doseBadge can be configured to meet the ISO Q=3 (for European regulations) and OSHA Q=5 (for the American standards).
The Exchange Rate, Criterion Level, Criterion Time, Threshold and Slow Time Weighting can be set individually in order to meet other standards such as those published by MSHA, AICHE and ACGIH. See the Noise Regulations page for more information.
As the doseBadge has Dual Channels, it can have Channel 1 set to OSHA, MSHA, AICHE, ACGIH or similar, with Channel 2 fixed to measure with the common ISO 3dB settings.
Applicable Standards
IEC 61252:1993 Personal Sound Exposure Meters
ANSI S1.25:1991 Personal Noise Dosimeters Class Designation 2AS-90/80-5
RC:110A: Internal Acoustic Calibrator to IEC 60942:2003 Class 2
Measurement Range (Typical)
70dB(A) to 130dB(A) RMS, 120dB(C) to 140dB(C) Peak
Measurement Functions
Overall Measurement Data
doseBadge Configuration (Serial Number, Date & Time)
Calibration Record
Measurement Duration
Highest Peak(C) Sound Level during the measurement
Overload Exceedence
115dB(A) Maximum Sound Level Exceedence
Battery Status
1 Minute Time History of:
LAeq (3dB) or LAVG (4dB or 5dB), Peak(C) Sound Pressure & Battery Level
For 3dB Exchange Rate:
LAeq, LEX,8h, LAE, % Dose, Exposure (Pa2h), Estimated % Dose,
Estimated Exposure (Pa2h)
For 4dB & 5dB Exchange Rates:
LAVG, TWA, % Dose, Estimated % Dose
Frequency Weightings
‘A’ for all RMS measurements
‘C’ for Peak Sound Pressure
Configuration Options
Channel 1: Independent User Configuration of:
Exchange Rate: 3dB, 4dB or 5dB
Criterion Level: 80dB, 85dB, 90dB
Criterion Time: 8hrs, 12hrs, 16hrs, 18hrs
Threshold: None, 80dB, 90dB
Time Weighting: None, ‘S’ (Slow)
Memory
CR:110A doseBadge
The CR:110A doseBadge can store up to 24 hours of data in a single measurement
RC:110A Reader
Up to 999 Individual doseBadge Measurements
Power
RC:110A doseBadge
Internal NiMH Battery. Typical Battery Life 24 hours @ 80dB
RC:110A Reader
2 x AA/LR6 with Auto Power Switch Off
CU Series Chargers
CU:195A Mains Power Supply. Fast Charge Option
Output
CR:110A doseBadge
Wireless Infrared to RC:110A Reader Unit
RC:110A Reader
USB 2.0 (which also provides power to the RC:110A Reader)
Dimensions
CR:110A doseBadge
Microphone Apex dia 13.0mm, Base 47mm dia, Height 38mm
Weight
CR:110A doseBadge 51g (1.8oz)
RC:110A Reader 400g (14oz)
Temperature
-10
Original doseBadge User Manual
English
German
French
Original doseBadge Datasheet
English
German
French