The doseBadge
Noise DosimetersThe latest doseBadge Noise Dosimeter combines the proven benefits of the iconic, original doseBadge personal noise dosimeter with a new generation of measurement, monitoring and connectivity features. Designed for demanding occupational noise environments, the doseBadge provides:
- Four integrators, multiple Peak and SPL measurement channels for comprehensive personal noise exposure monitoring
- Advanced Bluetooth advertising for live measurement and status data
- doseHub cloud connectivity for live access and completed measurements from anywhere
- Supports a wide range of international standards and regulations, including ISO standards, UK Control of Noise at Work Regulations 2005, EU Noise Directive 2003/10/EC, OSHA, MSHA, ACGIH, NIOSH, and AS/NZS 1269.1:2005
- Meets the latest IEC 61252:2025 standard
- Automatic measurement start and stop
- Up to 35 audio recordings per measurement, each up to 15 seconds, with configurable triggers and pre-trigger recording
- Selectable LED behaviour (All, Minimal, Off) for a more discreet badge
- Rugged metal enclosure designed for demanding working environments
- Over 24 hours of battery life
- Shipping from 9th, November 2026
The doseBadge
Next-generation personal noise exposure monitoring
The latest doseBadge Noise Dosimeter system is designed to provide a flexible and comprehensive solution for measuring workers’ personal noise exposure. Building on the proven doseBadge platform, the doseBadge combines a compact, cable-free design with enhanced measurement capabilities, advanced Bluetooth connectivity and new ways to monitor and control measurements.
With four integrators, multiple peak and SPL channels, extended battery life and up to 24-hour measurement periods, the doseBadge provides the information needed to assess occupational noise exposure across a wide range of working environments.
The doseBadge is designed to meet the very latest IEC 61252:2025 standard for personal sound exposure meters.
Supports a wide range of international standards and regulations, including ISO standards, UK Control of Noise at Work Regulations 2005, EU Noise Directive 2003/10/EC, OSHA, MSHA, ACGIH, NIOSH, and AS/NZS 1269.1:2005.
The doseBadge can be controlled using dBControl and the MyCirrus app, while advanced Bluetooth advertising and doseHub provide access to live measurement information without requiring a direct connection to the badge.
What's new with the doseBadge?
The doseBadge introduces a range of new features designed to make personal noise exposure monitoring easier to manage, while providing greater visibility of measurements throughout the working day.
- Advanced Bluetooth Advertising
Receive live badge information such as exposure, battery status and memory without needing to establish a direct connection. - Audio Recording
Capture triggered 15-second audio events, including 5 seconds of pre-trigger audio, to help investigate significant noise events. - Hearing Protection Data
Take hearing protection attenuation into account when assessing exposure, providing a more representative view of the protection being used. - Automatic Dock Start & Stop
Configure the badge to automatically start when removed from its dock and stop when returned, with an optional delay. - Improved Measurement Recovery
If power is unexpectedly lost, the doseBadge attempts to recover as much measurement data as possible.
Built for demanding working environments
The doseBadge has been designed with the demanding conditions of occupational noise measurement in mind.
The compact design keeps the badge comfortable to wear while protecting the electronics from the knocks and impacts encountered in the workplace.
Applications for the doseBadge Noise Dosimeter
The doseBadge provides personal noise exposure measurements for a wide range of occupational noise and industrial hygiene applications, including:
- Occupational noise exposure assessment: Monitor and assess individual workers’ exposure to noise throughout their working day.
- Noise at Work compliance: Support workplace noise assessments and occupational noise exposure programmes.
- Industrial hygiene: Collect personal noise exposure data as part of wider workplace health and safety assessments.
- Long-term noise exposure monitoring: Use scheduled measurements and extended battery life to monitor exposure across working shifts.
- Live exposure monitoring: Use advanced Bluetooth advertising, doseHub and MyCirrus to access mid-shift measurement information from badges within range.

View exposure adjusted for the protection being worn
Using the doseBadge Noise Dosimeter
The innovative doseHub is a compact receiver, powered by PoE or a mains adapter and connected via Ethernet or WiFi. It listens continuously for any doseBadge advertising within range and uploads data to the organisation’s MyCirrus cloud portal, giving supervisors and Health & Safety officers real-time visibility of exposure across a site (or across multiple sites) from anywhere in the world.
With the new Nearby function, finding a specific doseBadge is even easier. Rather than searching through every badge within range, Nearby mode identifies the badge with the strongest signal, helping users quickly connect to the badge closest to them.
Configure your doseBadge your way
From exposure calculations and warning levels to audio triggers and hearing protection, the doseBadge provides flexible configuration options to suit your measurement requirements. Settings can be managed through the MyCirrus app, giving users control over how the dosimeter operates before and during measurements.
- Measurement Settings
Configure the measurement parameters and integrators required for your application. - Audio Triggers
Set the noise threshold and minimum duration required to trigger an audio recording. - Hearing Protection
Apply SNR, HML or octave-frequency attenuation to account for hearing protection. - Dose Warnings
Set the dose level at which the badge provides a warning, including an assumed hearing protection level where required. - LED Control
Choose between All, Minimal or Off LED operation while measuring. - Automatic Start & Stop
Configure the badge to start when removed from the dock and stop when returned.
Learn more about our doseBadge
If you would like to learn more, a member of our team will be happy to help
The doseBadge is a personal sound exposure meter (PSEM), also known as a noise dosimeter. It is designed to measure and record a worker’s personal noise exposure throughout their working day. The doseBadge can perform up to four different exposure calculations simultaneously, known as integrators, making it suitable for different occupational noise measurement requirements.
The doseBadge introduces a range of new features and improvements, including advanced Bluetooth advertising, audio recording, hearing protection adjustment, automatic start and stop when using the charging dock, improved measurement recovery and greater control over the badge’s LEDs. It also removes the need to clear stored measurements when making many setting changes.
Advanced Bluetooth advertising allows the doseBadge to transmit changing information every few seconds, including live exposure, battery status and available memory. A compatible receiver only needs to be within Bluetooth range briefly to receive this information; a direct connection to the badge is not required for live data. A Bluetooth connection is still required for functions such as starting, stopping or pausing a measurement and for transferring complete measurement data.
Yes. Audio recording is a new feature for the doseBadge platform. Audio recordings can be triggered when a configured noise threshold is exceeded for a specified duration. The doseBadge can store up to 35 audio events, with each recording lasting 15 seconds and including 5 seconds of pre-trigger audio.
Yes. The doseBadge can provide live exposure information adjusted for the hearing protection being worn. NoiseTools supports hearing protection adjustments using SNR, HML or octave-frequency attenuation, with a library of hearing protection options as well as the ability to add user-defined values. These adjusted values can also be displayed through dBControl, the MyCirrus portal and NoiseTools.
Yes. The doseBadge can be configured to automatically start a measurement when it is removed from the dock and stop the measurement when it is returned. An optional delay can also be added to the automatic start, making the feature useful for teams with flexible working shifts. Scheduled measurements can also be configured to run while the badge is on the dock.
The doseBadge provides over 24 hours of battery life, supporting full-shift personal noise exposure measurements without the need for frequent recharging.
The doseBadge can store up to 40 measurements, with a maximum measurement duration of 24 hours for an individual measurement.
No special training is required. The system is designed to be simple, intuitive, and easy to operate with minimal instruction.
Yes, it is used across manufacturing, construction, utilities, transportation, and any other sectors where noise exposure monitoring is critical.
Applicable Standards:
- IEC 61252:2025 Personal Sound Exposure Meters
- ANSI S1.25:1991 (R2007) Personal Noise Dosimeters
Measurement Range (typical)
- RMS Range: 60dB(A) to 140 dB(A)
- Peak Range: 80dB(C) to 143 dB(C)
- RMS Frequency Weighting: A, C, or Z
- RMS Time Response: F or S
- Peak Frequency Weighting: A, C or Z
- Linear Operating Range (A): 60dB(A) to 140dB(A)
- Linear Operating Range (Z): 60dB(Z) to 140dB(Z)
Visual Indication of Status
- Four-colour LED to show status and activity
Measurement Functions
- Simultaneous measurement of:
- Four independent Integrator channels
- Three independent Peak channels (A, C, Z)
- Six SPL min and max channels (LAF, LSF, LCF, LCS, LZF, LZS overall)
Overall measurement data
- Measurement duration
- Start time and date
- Instrument serial number and name
- Calibration information (field and factory calibration)
- Overload and tamper sensor detection
For each integrator channel
- Average integrated sound level (Leq/LAVG)
- Time weighted average (LEP,d/LEX, 8/TWA)
- Sound exposure and estimated sound exposure
- % dose and estimated % dose ULT duration
Time History Data
- 1 Second time history data
For each integrator channel
- Integrated Sound Level (leq/LAVG)
Integrator Channels:
- Channel name: pre-set or user-defined
- Exchange rate: 3, 4, 5 or 6 dB
- Criterion Level: 80dB to 100dB in 1dB steps
- Criterion Time: 1 hr to 24 hrs in 1 hr steps
- Threshold Level: None, 70dB to 100dB in 1dB steps
- Time Weighting: Fast, Slow, or None
- Frequency Weighting: A, C or Z
- ULT Level: 70dB to 100dB in 1dB steps
- ULT Time Weighting: Fast, Slow or None
- ULT Frequency Weighting: A,C or Z
- LED Threshold Trigger: User-selectable channel with user-selectable %
- Dose trigger levels 75% to 100% in 5% steps
Peak Channels
- Frequency weighting: A, C and Z (all recorded)
Software
- NoiseTools software supplied as standard with license-free installation and free of charge upgrades available from the Cirrus Research website
Measurement Control(Manual)
- Start, stop, pause and resume
Automatic Scheduled Measurements
- Timed start, pause and stop of measurements
- Up to 24 different timers each start, stop, pause, resume counts as one
- Up to 3 pauses can be set (maximum 2 hr pause)
- Days of the week can be selected and repeated weekly
Shock/Tamper Sensor
- Internal accelerometer with Off/Low/Medium/High sensitivity settings to detect impact and tampering. Detected impacts are marked on time history data in NoiseTools in red
- A red LED can be configured to flash when a tamper event is detected
Calibration
- Automatic detection of external acoustic calibration
User-configurable calibration level
- Default set to 94dB suitable for CR:514 acoustic calibrator
- Can be set to 114dB suitable for dual level CR:516 calibrator
- Up to 74 hours of Time History Data. Up to 40 individual measurements
- Maximum durtaion of any single measurement is 24 hours
Audio
- Up to 35 recordings up to 15 seconds each (including 5 seconds pre-trigger)
- Audio triggers can be configured in NoiseTools
- Configuration options for overwriting audio: disabled, oldest overwritten, lowest max level overwritten, lowest average cannot be overwritten
- Audio events from previous measurements cannot be overwritten
Power
- CR:130A doseBadge
- Internal Lithium Polymer (LiPo) Battery 3.7V 630 mAh
- Typical Battery Life >24 hours
- Typical 3 hours charge time from empty to approx. 90%
- Charging should be carried out where the ambient temperature is between 18°C and +35°C (+65°F to +95°F)
Communication
- Bluetooth
- USB download to NoiseTools via the doseBadge dock
Weight and Dimensions
- CR:130A doseBadge only
- 47(l) x 47(w) x 44(h)mm (excluding strap, sealing baseplate the windshield)
- 175(l) x 70(w) x 60(h) mm (including strap, sealing baseplate the windshield)
- 1.85”(l) x 1.85”(w)x 1.73”(h) (excluding strap, sealing baseplate the windshield)
- 6.89”(l) x 2.76”(w)x 2.36”(h) (including strap, sealing baseplate the windshield)
- 50g/1.8 oz (excluding strap, sealing baseplate the windshield)
- 85g/3.0 oz (including strap, sealing baseplate the windshield)
Temperature
- -10°C to +50°C (+14°F to +122°F) Operating
- -20°C to +60°C (-4°F to +120°F) Storage
Humidity
- Up to 95% RH Non-Condensing